💡 At a glance · ONDA is a 2.45 GHz microwave (Coolwaves) device developed by DEKA in Italy. It selectively heats the subcutaneous fat layer to treat localized fat, cellulite and skin laxity in one non-surgical session. · The key difference from look-alike devices is not the frequency number but the handpiece. ONDA's coaxial design pairs an emitting electrode with a return electrode, so microwaves that pass through tissue come back to the handpiece, reducing energy loss and exposure of surrounding tissue. · Per manufacturer data, about 80% of the energy is delivered to fat and only 20% to the dermis, while built-in contact cooling protects the epidermis. · Evidence: median abdominal circumference reduction of 3.9 cm (Bonan et al., 2019); severe cellulite falling from 30% to 0% (Nisticò et al., 2022); no serious adverse events in published studies. · One-line takeaway: sharing "2.45 GHz" does not make two treatments the same. Check four things: handpiece design, cooling, clinical data and regulatory clearance.
What exactly is ONDA?
ONDA (Onda Coolwaves, ONDA Lifting, Coolwaves, microwave lifting, 온다 리프팅, オンダ, 微波拉提) is a non-surgical body and face contouring device that delivers 2.45 GHz microwaves into the fat layer beneath the skin and selectively heats fat cells. It first established itself in Europe as a body-shaping platform; in Korea it is better known as "ONDA Lifting" for the jawline, double chin and sagging cheeks. Among international patients visiting Korea it is one of the most asked-about lifting treatments, because it needs no numbing, has no downtime and lets you return to your schedule the same day.
If you search for ONDA today you will also find other microwave devices that describe a similar principle. From a patient's point of view it is natural to wonder whether any 2.45 GHz microwave device is the same treatment. This article answers that question.
| Item | Detail |
|---|---|
| Type | Non-surgical energy-based treatment (microwave) |
| Mechanism | Dielectric heating by 2.45 GHz microwaves, selectively targeting subcutaneous fat and the lower dermis |
| Duration | Depends on energy delivered (kJ) and area; confirmed at consultation |
| Anesthesia | Not required (no numbing cream) |
| Downtime | None; back to daily life the same day |
| Discomfort | 2–4/10; alternating warmth and cooling |
| Onset | Jawline definition within 1–2 weeks; collagen-related firming over 1–3 months |
| Longevity | Fat reduction is long-lasting if weight is maintained; firming effect 6–12 months |
| Sessions | Face: visible change from a single session; body: additional sessions depending on fat volume |
| Indications | Double chin, jawline fullness, sagging cheeks; localized fat on abdomen, thighs, arms; cellulite; skin laxity |
| Not recommended | Pregnancy or breastfeeding; active dermatitis or infection. Implanted electronic devices or metal implants are relative contraindications, decided by the doctor after review |
What are "2.45 GHz microwaves", and how do they differ from RF and ultrasound?
Microwaves are electromagnetic waves in the same band (2.45 GHz) used by a kitchen microwave oven. As the waves pass through tissue, molecules oscillate rapidly and generate frictional heat, a process called dielectric heating (the material heats itself from within). Conventional radiofrequency (RF) lifting uses 0.1–40 MHz; its energy is consumed first in the water-rich epidermis and dermis, so its action is dermis-centered. ONDA uses a frequency roughly 100 times higher, allowing energy to pass through the dermis into the subcutaneous fat.
According to the manufacturer, about 80% of the energy from the ONDA handpiece is absorbed in the fat layer and about 20% in the dermis. To be precise, water molecules also absorb 2.45 GHz, so "it heats only fat" is not accurate. Fat has little blood flow and cannot dissipate heat well, so its temperature rises further, while the epidermis is cooled by contact cooling. The net result is heat concentrated in fat, and achieving that balance is the job of handpiece design and the cooling system.
The international advisory board recommendations compiled by Nisticò et al. (2024, Bioengineering) describe ONDA as a 2.45 GHz device with up to 200 W output, and explain that this frequency, combined with "the special shape of the coaxial emission handpiece", can be directed at the subdermal fat layer. In other words, the frequency alone is not the point; the combination of frequency and handpiece is.
Key difference 1: a handpiece that "recovers" the microwaves
The ONDA handpiece arranges an emitting electrode, which sends energy out, and a return electrode, which receives energy that has passed through tissue, in a coaxial layout with the cooling system between them. Put simply, the microwaves do not radiate away in one direction; they leave the handpiece, travel through tissue and come back to the handpiece in a closed path.
This matters to patients for three reasons.
First, where the energy goes is defined. In a simple antenna-type radiating design with no return electrode, it is hard to predict how far the microwaves spread within tissue, and depth control depends on power settings. With ONDA, treatment depth is set at the design stage by handpiece type (3 mm or 7 mm; Shallow or Deep).
Second, less energy leaks to the surroundings. In any microwave device, energy that is reflected or scattered rather than absorbed can reach unintended areas of the patient or the operator. A design that brings reflected waves back to the handpiece works to reduce that leakage.
Third, the system can "read" the tissue. In microwave engineering, reflected power is a signal of impedance mismatch (a difference in electrical resistance between tissue and device). A high reflected component means energy is not entering the tissue properly, and unmanaged reflected power overheats cables and the generator. A device with a return path can use this signal to keep output stable.
Key difference 2: same frequency, different results. Seven things to check
A microwave generator in itself is not special technology. The 2.45 GHz band is open for industrial, scientific and medical use, so any manufacturer can use it. The difference lies in how many millimeters below the skin the energy is delivered, how evenly, and how well the epidermis is protected while doing so. These are the items worth asking about at consultation.
| Item | ONDA (DEKA) | What to check on other microwave devices |
|---|---|---|
| Handpiece design | Coaxial emitting and return electrodes, patented | Is there a return electrode? Is depth defined by design? |
| Depth selection | Dedicated 3 mm (lower dermis, firming) and 7 mm (fat) handpieces | Are there depth-specific handpieces, or is depth controlled only by power? |
| Epidermal protection | Contact cooling built into the handpiece | Cooling method and real-time temperature control |
| Maximum output | 200 W | Is output and the energy unit (kJ) disclosed? |
| Clinical evidence | Multiple peer-reviewed papers since 2019; international advisory board recommendations (2024) | Are there published clinical studies under that device's name? |
| Regulatory status | CE (Europe), FDA clearance (Onda Pro, US), MFDS approval (Korea) | MFDS approval and the approved scope of use |
| Consumables and authenticity | Genuine handpieces and tips, manufacturer training | Source of handpieces and replacement intervals |
This table is not meant to put any specific device down. Any device that discloses these items transparently and accumulates clinical data is a good device. It is, however, worth knowing that ONDA is currently the representative 2.45 GHz aesthetic device with repeated peer-reviewed publications.
Safety: how real is the burn concern?
Every heat-based treatment carries a theoretical burn risk. Microwaves are no exception, and ONDA consent forms also state a rare possibility of thermal injury. What matters is how far design and protocol reduce that possibility.
ONDA's safety relies on three layers: a frequency and handpiece combination that concentrates energy in fat rather than dermis, contact cooling that lowers epidermal temperature, and a protocol that measures total energy in kJ (kilojoules) and distributes it by area. In the histological examination by Nisticò et al. (2022, Journal of Clinical Medicine), no epidermal or dermal damage was seen either immediately after treatment or two months later, and the inflammatory response had fully resolved. No serious adverse events were reported in that study, and the 16-patient study by Arrigoni et al. (2024, Journal of Cutaneous and Aesthetic Surgery) recorded zero adverse effects.
The common reactions are redness, warmth, mild tenderness and temporary dryness lasting from a few hours to one or two days. Treatment is avoided during pregnancy or breastfeeding and in areas with active dermatitis or infection. Implanted electronic devices or metal implants are relative contraindications: the doctor reviews their location and type before deciding.
One honest caveat: the 2024 advisory board paper supports ONDA's efficacy and safety but explicitly notes that long-term (multi-year) data are still lacking. Published follow-up periods are generally 2–9 months. This is not unique to ONDA; most non-surgical body contouring devices share the same limitation.
Results: what the numbers say
Rather than calling results "good", here are the figures.
For localized fat, Bonan et al. (2019, Dermatologic Therapy) reported a median abdominal circumference reduction of 3.9 cm (range 1.5–7 cm) and a trochanteric reduction of 2.8 cm at week 8 after four sessions. Arrigoni et al. (2024) reported that after four sessions at 30-day intervals, mean abdominal circumference fell from 96.6 cm to 94.6 cm and ultrasound-measured abdominal fat thickness decreased from about 1.3 cm to 0.9 cm. In the 9-month follow-up by Coli et al. (2023, Dermatologie), circumference reduction was maintained as long as there was no significant weight gain.
For cellulite, Nisticò et al. (2022) treated 26 women with four sessions at 30-day intervals and reported that the share of severe cellulite fell from over 30% to 0% at three months. Patient satisfaction cited in the 2024 advisory board paper was 4.1 out of 5.
These studies used multi-session designs, but in practice many patients notice jawline and double-chin contour changes after a single session. Clinical experience on the face in Korea centers on the jawline, double chin and cheek sagging: the 7 mm handpiece reduces submental fat and the 3 mm handpiece induces collagen contraction and remodeling in the lower dermis. Jawline definition tends to appear relatively quickly, with firming over 1–3 months. Peer-reviewed data on facial indications are fewer than for the body, so this part should be read as clinical experience rather than trial evidence.
How DIORE approaches it
In our practice we treat ONDA as "lifting for areas that have fat". For patients whose cheeks and submental fat make the facial line look heavy, ONDA is the first card we reach for. For patients with little cheek fat and thin skin, we recommend ultrasound- or RF-based lifting such as Ultherapy, Thermage or Sofwave first, or combine them, rather than ONDA alone. Putting a lot of microwave energy into an area with little fat only increases the thermal load relative to the benefit.
For international patients making a single visit to Korea, ONDA is attractive because there is no numbing and no downtime, so you can continue your day right after treatment. When combined with an injectable such as Re2O on the same day, the energy-based ONDA goes first and injections last. During treatment we use the patient's heat feedback as the most important safety signal, and we keep in mind that the cooler the surface feels, the more carefully the operator must manage the temperature of the layer beneath. The device and handpieces can be shown to you at consultation on request.
Frequently asked questions
Q1. Does ONDA Lifting work after a single session, and when do results show?
Many patients notice jawline and double-chin contour changes within 1–2 weeks of one session, while firming appears over 1–3 months as collagen remodeling progresses. Published body studies measured circumference reduction from the second of four sessions, with maximum effect reported 4–8 weeks after the last session. If you are visiting once, energy is allocated to your fat volume at consultation, and any additional treatment is planned for a future visit if needed.
Q2. ONDA vs Thermage: which is better?
They target different layers. Thermage heats the dermis with monopolar RF and excels at tightening the skin itself and improving fine lines; ONDA acts on the lower dermis and subcutaneous fat and excels at refining contours where fat is present. Cheek or submental fat points toward ONDA; thin skin with sagging and fine lines points toward Thermage. The two are also combined.
Q3. Can I get burned from ONDA?
Theoretically possible, but no cases were reported in published clinical studies. The premise is that contact cooling and kJ-based energy allocation are working and that output is adjusted immediately if you feel it is too hot. Redness and warmth after treatment usually settle within hours to 1–2 days; blistering or persistent pain should be reported right away. For one week, avoid saunas, alcohol and intense exercise, and keep up moisturizer and sunscreen.
Q4. What does kJ (kilojoule) mean, and how many do I need?
kJ is the total energy delivered to tissue during treatment, the way Ultherapy counts "lines". The face is usually treated with several tens of kJ split across jawline, cheeks and chin; the body uses more depending on area size. The same kJ can produce different results depending on handpiece depth and distribution, so rather than comparing numbers alone, ask which handpiece will deliver how much to which area.
Q5. How do I confirm it is a genuine ONDA?
Check the DEKA logo and model name on the main unit (ONDA, ONDA Plus, ONDA Pro) and the 3 mm/7 mm or Shallow/Deep marking on the handpieces. Officially imported devices in Korea carry an MFDS approval number, which the clinic can show you on request. If a menu says only "microwave lifting" or "2.45 GHz lifting" without naming the device, ask which device it is.
Conclusion
The difference between ONDA and other microwave devices lies beyond the number "2.45 GHz": in the handpiece design that decides where energy goes and where it returns, in the cooling that protects the epidermis, and in the clinical papers showing what that combination actually did for patients. Simply asking about the device name, handpieces, regulatory approval and published studies at consultation gets you much closer to a good choice. At DIORE Clinic we look first at fat distribution and skin thickness to judge whether your face is a good match for ONDA.
Related articles: Onda vs Titanium Lifting: What's the Difference?, ONDA Coolwaves in Seoul: How It Reduces Fat and Cellulite, Thermage Moving Shot vs Stamping Shot: Why Results Differ
ℹ️ This content is for general medical information and does not replace an individual consultation. Results vary with each person's skin, and an accurate assessment should be made together with an aesthetic medicine specialist.
References
- Bonan P, Marini L, Lotti T. Microwaves in body sculpting: A prospective study. Dermatologic Therapy. 2019;32:e12782.
- Nisticò SP, et al. Microwave Therapy for Cellulite: An Effective Non-Invasive Treatment. Journal of Clinical Medicine. 2022;11(3):515. doi:10.3390/jcm11030515
- Arrigoni F, Fusco I, Zingoni T, Massirone A. Non-invasive system delivering microwaves energy for localized adiposity reduction, skin laxity, and cellulite: Clinical evidence. Journal of Cutaneous and Aesthetic Surgery. 2024. doi:10.25259/JCAS_7_2024
- Coli F, et al. Results on reduction of subcutaneous adipose tissue using a novel body contouring system based on microwave technology. Dermatologie. 2023.
- Nisticò SP, et al. Microwave-Energy-Based Device for the Treatment of Cellulite and Localized Adiposity: Recommendations of the "Onda Coolwaves" International Advisory Board. Bioengineering. 2024;11(12):1249. doi:10.3390/bioengineering11121249
- Salsi B, Fusco I. Non-invasive system delivering microwaves energy for unwanted fat reduction and submental skin tightening: clinical evidence. Journal of Cosmetic Dermatology. 2022;21:5657-64.